Duplex Stainless Steel Small Buffer Tank for Gas Boiler

Product Details
Customization: Available
Material: Stainless Steel
Certification: ISO9001, CE, CCC
Shipping
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Guarantee
Payment Methods:
T/T PayPal ApplePay GooglePay visa mastercard american express discover
JCB diners club PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (22)
  • Duplex Stainless Steel Small Buffer Tank for Gas Boiler
  • Duplex Stainless Steel Small Buffer Tank for Gas Boiler
  • Duplex Stainless Steel Small Buffer Tank for Gas Boiler
  • Duplex Stainless Steel Small Buffer Tank for Gas Boiler
  • Duplex Stainless Steel Small Buffer Tank for Gas Boiler
  • Duplex Stainless Steel Small Buffer Tank for Gas Boiler
Find Similar Products
  • Overview
  • Product Description
  • Specification
Overview

Basic Info.

Model NO.
BT-304/300
Usage
Solar Water Heater
Inner Material
Stainless Steel 304 or 316L
Insulation Layer
Polyurethane Foam
Outer Shell
Color Steel
Max Capacity
500L
Thickness of Foam
50mm
Working Pressure
6.0 Bar
Application
Heat Pump System, Domestic Hot Water
Transport Package
Inner Poly Bag with Outer Export Carton Packing
Specification
ISO, CE
Trademark
INLIGHT
Origin
China(Mainland)
HS Code
841990
Production Capacity
5000 Units/Month

Packaging & Delivery

Package Size
183.00cm * 66.00cm * 66.00cm
Package Gross Weight
60.000kg

Product Description

Product Description
Duplex stainless steel small buffer tank for gas boiler
INLIGHT manufactures a large range of stainless buffer tanks with different coil configurations.
Heating Systems: In heating systems, a buffer tank stores excess hot water produced by a boiler or heat pump. This helps to prevent short cycling of the heating equipment, which can lead to inefficiencies and wear.
Cooling Systems: In chilled water systems, a buffer tank stores cold water to ensure consistent cooling, compensating for fluctuations in cooling demand.
Specification
Product Range
Buffer Tank
Tank Material
SUS304/SUS316L/Duplex Stainless steel
Volume Range
50L-500L
Outer shell
Color board or Stainless steel
CONNECTIONSNS
1/2”, 3/4”, 1”, 5/4”, 6/4”, 2”
Working Pressure
0.6 MPa
Maximum Pressure
1.0 Mpa
Duplex Stainless Steel Small Buffer Tank for Gas Boiler
How do heat pump buffer tanks work?

1. A buffer tank works by storing hot water to satisfy the system's requirements during ASHP defrosting cycles.
2. It reduces the short cycling of the heating system and improves heat pump performance.
3. The buffer tank provides a "heat sink" and "heat source" for excess heat energy.
4. It helps to smooth out changes in heat demand and loading on the heat pump.
 Feature 
Duplex stainless steel 2205 surge tanks will never corrode and weigh half as much as steel surge tanks. These benefits can reduce labor costs for installation while being a cost-effective way to increase system efficiency by reducing heat pump short cycling during low load periods and hydraulically decoupling the source from the distribution system. Our NSF certified polypropylene core is rated to 180 degrees Fahrenheit at 75 PSI and 140 degrees Fahrenheit at 100 PSI, surrounded by a continuous fiberglass and high temperature resin blend, making SST surge tanks ideal for hydronic and geothermal heating and cooling, low mass boiler systems, and chilled water applications. Argosy tanks are insulated with closed cell foam to provide R-values unmatched by competitors with heat losses of less than 1 degree/hour. 
 
Operation: The primary purpose of a buffer tank is to reduce short cycling of a heat pump, chiller or boiler. A hydraulic buffer tank is used in systems that experience below design load conditions most of the time, or in systems that call for multiple low BTU cooling or heating loads at different times. This can cause the heat pump or boiler to short cycle, which reduces operating efficiency and shortens the life of the equipment.
 
What It does: The buffer tank has 4 connections built into it. Two connections can be piped to the heat pump or boiler and two connections can be piped to the distribution system. If piped correctly, the tank can act as a thermal buffer and a hydraulic decoupler. The heat pump or boiler can be hydraulically decoupled from the distribution system.
Duplex Stainless Steel Small Buffer Tank for Gas Boiler
Duplex Stainless Steel Small Buffer Tank for Gas Boiler
Duplex Stainless Steel Small Buffer Tank for Gas Boiler
Duplex Stainless Steel Small Buffer Tank for Gas Boiler

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Send Inquiry
Chat Now